ACT-Machine

(2 customer reviews)

An ACT machine, or activated clotting time machine, is a medical device used to measure the time it takes for blood to clot after being activated. This test is used to monitor the effects of heparin, an anticoagulant medication that is used to prevent blood clots.

ACT machines work by taking a blood sample and adding an activator to it. The activator causes the blood to clot, and the machine measures the time it takes for the clot to form. The normal ACT range is 25-35 seconds. If the ACT is too low, it means that the patient is not receiving enough heparin and is at risk of developing a blood clot. If the ACT is too high, it means that the patient is receiving too much heparin and is at risk of bleeding.

ACT machines are used in a variety of settings, including hospitals, clinics, and emergency departments. They are also used in some home health care settings.

Here are some of the benefits of using an ACT machine:

It is a quick and easy test to perform.
It can be used to monitor the effects of heparin in real time.
It is a reliable and accurate test.
Here are some of the limitations of using an ACT machine:

The results of the test can be affected by the patient’s blood temperature.
The test can be affected by the type of activator that is used.
The test is not as sensitive as other tests for detecting blood clots.
Overall, ACT machines are a valuable tool for monitoring the effects of heparin therapy. They are quick, easy, and reliable, and they can be used in a variety of settings.

Here are some additional details about ACT machines:

The most common activator used in ACT machines is kaolin. Other activators that can be used include glass beads, celite, and ellagic acid.
The ACT results are typically reported in seconds.
The ACT machine must be calibrated regularly to ensure accurate results.
ACT machines are typically used in conjunction with other tests, such as the partial thromboplastin time (PTT), to monitor the effects of heparin therapy.

SKU: ATM MEDICALS FZC Refurbished ACT-Machine Categories: , Tag:
Compare

How does an ACT machine work?
An ACT machine works by taking a blood sample and adding an activator to it. The activator causes the blood to clot, and the machine measures the time it takes for the clot to form. The most common activator used in ACT machines is kaolin. Other activators that can be used include glass beads, celite, and ellagic acid.

What is the normal ACT range?
The normal ACT range is 25-35 seconds. However, the target ACT range may vary depending on the patient’s condition and the type of surgery they are having. For example, the target ACT range may be higher for patients who are at high risk of developing blood clots.

What are the benefits of using an ACT machine?
There are several benefits to using an ACT machine:

* It is a quick and easy test to perform.
* It can be used to monitor the effects of heparin in real time.
* It is a reliable and accurate test.
What are the limitations of using an ACT machine?
There are a few limitations to using an ACT machine:

* The results of the test can be affected by the patient’s blood temperature.
* The test can be affected by the type of activator that is used.
* The test is not as sensitive as other tests for detecting blood clots.
What are some other uses for ACT machines?
In addition to monitoring the effects of heparin therapy, ACT machines can also be used to monitor the effects of other anticoagulant medications, such as warfarin. ACT machines can also be used to diagnose certain bleeding disorders.